How to Fix
- 1
Check connector between display PCB and Wi-Fi modem lead wire for loose connection; reconnect if loose.
- 2
With Wi-Fi function on, measure voltage at Wi-Fi modem CON802 pins 5–6: expected not 0V and not 5V. If static (0V or 5V), replace Wi-Fi modem.
- 3
Check Display PCB output at CON802 pins 1–4: expected 5V. If not 5V, replace Display PCB.
- 4
Check Display PCB output at CON802 pins 2–4: expected not 0V and not 5V. If static, replace Display PCB.
- 5
If all voltages are correct: explain to customer.